Eight channel Versatile Input Pre-amplifier
VIP80S
 

VIP80S

An 8 channel pre-amplifier specially designed for those situations where some signal gain is required or where a transducer output is incompatible with your instrumentation input.

It has been specifically developed as a go anywhere, no- nonsense, sensible utility which will act as an instrumentation amplifier, an anti-alias filter, an isolation unit, an accelerometer interface, a differential to single ended convertor and an overload detector.

For instance, if vibration is to be measured, simply connect an ICP accelerometer direct to the VIP which can provide the necessary interf ace and give you a calibrated gain of up to 60dB.

Specification
No of channels 8
Gain Switchable -20dB, -10dB, 0dB, 10dB, 20dB, 30dB, 40,dB, 50dB, 60dB
Gain accuracy +1%
Bandwidth Low frequency: dc coupling: dc
  ac coupling: 0.5Hz (3 dB)
High frequency: 25 KHz: 3dB (±1dB)
Filter Analogue low pass 4 pole Butferworth 3 dB point: 25 KHz
Note: 8 pole filter (48 dB/oct.cutoff) performance obtained by connecting both channels in series.
Input Differential, AC or DC coupled (Switchable)
Common mode AC coupling isolation: ± 1OOV pk
ICP input, AC coupled
Input Impedance l Mohm
Input range ±10V max.
Input offset (1 + 5/G)mV max. (G = gain)
Output ±7V max swing.
Overvoltage LED indication for output greater than 7.OV
CMRR at Gain=1: 70dBmin.
at Gain = 10: 87 dB min.
at Gain=100: lOOdBmin.
Noise 1 OuV pk-pk, rti. max.
Drift (5 + 100/G)uV/°C max.
Gain Drift 100ppm/°C max
Supply SONY Battery packs
Controls On/Of f switch
Per channel: Gain select rotary switch.
  DC/AC/ICP input selector.
  Diff/Single ended selector
Connectors Input: insulated BNC
Output: BNC
Operating temp. Operation within above spec.: 0 to +35°C
Operation, spec not guaranteed: -20 to +60°C

 

 


LAPLACE INSTRUMENTS LTD
3B, Middlebrook Way,
Holt Road, Cromer,
Norfolk, NR27 9JR,
UK
Tel: + 44 (0)1263 515160
Fax: + 44 (0)1263 512532
E-mail:
tech@laplace.co.uk

 
EMC Testing ICON

If you have any comments, suggestions regarding our site or  require further product  information please use the feedback form

Revised: October 14, 1999
Copyright © Laplace Instruments 1998, all rights reserved