PC controlled RF synthesisers for immunity testing up to 2.4GHz matched
to the requirements of IEC61000-4-3
and featuring automatic scanning to pre-programmed schedules.
The RF1000/RF2000 are signal sources matched to the RFI immunity requirements
of IEC61000-4-3.
Features such as sine and pulsed modulation, programmable start and
stop frequencies, frequency step, and dwell time are provided as standard.
These units are essentially the same except that the RF1000 covers
the range 30MHz to 1000MHz and the RF2000 covers 30MHz to 2400MHz. Both
include powerful Windows control software with USB port interface.
These synthesisers has been conceived with the practical user in mind.
To make the best use of the immunity test facilities for both compliance
testing and product investigations, several useful features have been
developed. These include:
| Specification: |
RF1000 |
RF2000 |
| Output carrier frequency: |
30MHz -1GHz |
30MHz -2.4GHz |
| Resolution: |
0.5% of current value |
| Step size: |
0.5% to 5% of current value |
| Level(carrier signal): |
-60dBm to 0dBm |
Indication:
|
Bargraph indication of level |
Control Mode:
|
Open loop (pre-programmed) or closed loop. |
| THD (worst case): |
10% |
| Modulation: |
off
1KHz sine 80% AM modulation
200Hz, 10Hz, 1Hz pulsed. 100% level |
| Output connector: |
BNC |
| Ext. feedback probe: |
Input 0-2V
Calibration via PC software. |
| Excitation Output: |
|
Output:
|
5V @ 20mA DC |
Connector:
|
5 pin circular |
8 pin circular |
EUT status:
|
5V relay input |
Fault modes:
|
Stop, pause, continue. |
Connector:
|
3 pin circular |
| EUT prompt: |
|
Output:
|
4 pole c/o volt free contacts. |
Modes:
|
Pulsed, Continuous, off |
Connector:
|
15 pin Dee Type |
| P.A. interlock: |
|
Input:
|
Contact closure enforces standby mode. |
Connector:
|
4 pin circular |
| |
|
| Control: |
From supplied PC software via standard
PC USB Port. |
| Environment: |
Windows 98, XP |
| Main control: |
Start test (RUN)
Stop test (STOP)
Pause at frequency (DWELL)
Single frequency mode
|
| Setup screen: |
Enables all parameters of a test sweep
and EUT details to be programmed. |
Parameters:
|
Start and end frequencies
Frequency step (% of current value)
Field strength (0-10V/m)
Dwell time (1 - 99 seconds)
Modulation mode. |
| Single freq. screen: |
Manually or automatically ramp the field
strength at one frequency. |
| Report screen. |
Plot all details of the test including
setup parameters, actual vs. target settings and EUT status. |
| Status window: |
Real time indication of operating mode,
EUT status and P.A. status. |
| |
|
| Menus: |
|
| File: |
All standard windows facilities, including
printer output and file Save, Open commands. Test results and setup
data can be stored / recalled separately. |
| Mode: |
Select operating mode and test sequence. |
| Config: |
Enter cell characteristics, Probe calibration,
P.A. characteristics. |
| Indication: |
Mains power
Output signal level (bargraph)
P.A. status, EUT status, EUT prompt. |
| |
|
| General: |
|
| Supply: |
110VAC or 230VAC 50 / 60Hz,
factory set. |
| Size: |
300 x 240 x 96 mm |
| Weight: |
4.5 kg |