A complete range for commercial, automotive and military applications.
- From single line up to 4 line.
- 16 Amps to 500 Amps.
- CISPR16, CISPR25, Def Stan, Mil Spec and specialist types supplied.
- All LISN'S supplied fully compliant and calibrated.
- All commercial types include transient limiter and feature 0dB
insertion loss.

CISPR16, single phase, 16 amp LISN
COMPREHENSIVE
The Laplace range of LISNs covers an exceptionally wide scope, covering
all applications from commercial and industrial to military , aerospace
satellite.
COMPLIANCE
All Laplace LISNs are fully compliant with the appropriate standard
and are shipped complete with calibration data.
PROTECTION
All standard CISPR16 LISNs are fitted with a transient limiter and
include a separate pre-ampflier to give a 0dB insertion loss.
CONVENIENCE
Commercial LISN'S are fitted with standard mains outlets. Country-specific
types can be specified at time of ordering. Single pole jack sockets
are normally also included so that individual conductors can be connected.
When measuring EMC emissions conducted from the equipment-under-test
(EUT) most standards specify a LISN (or artificial mains V-network)
to couple the RF from the cable and to provide a repeatable impedance
at the measured frequencies. All laplace LISN's fully comply with the
relevant standards and feature a rigorous, individual calibration with
hardcopy of results issued by a uk test laboratory.
| General Specifcations |
| RF Output socket: |
50 ohm, BNC for each line. |
| EUT line connections: |
Single pole shrouded sockets
< 32A = 4mm
> 32A = 6mm
Additionally for 16A type, domestic mains outlet
fitted. Specify UK, US, Schuko(Euro) or As/NZ type when ordering.
|
| Termination impedance: |
Internal |
| Ground bond: |
Stud terminal on front panel. |
| Artificial hand output: |
All CISPR16 LISNs fitted (220pF ||
510 ohms). |
| Operating temperature: |
-5°C to +40°C |
| Transient protection level: |
150dBuV |
| Earth Leakage current |
80mA |
Line voltage:
|
Single phase:
3 Phase: |
Up to 250V ac rms
Up to 415V ac rms |
| LISNs Specification |
| Model number |
Standard |
Current rating (Amps) |
Phases |
Internal Transient
limiter |
Frequency Range |
Size |
| LISN-16A1P |
CISPR16 |
16 |
L,N |
 |
150KHz- 30MHz |
A |
| LISN-32A1P |
CISPR16 |
32 |
L,N |
 |
150KHz- 30MHz |
B |
| LISN-63A1P |
CISPR16 |
63 |
L,N |
 |
150KHz- 30MHz |
B |
| LISN-100A1P |
CISPR16 |
100 |
L,N |
 |
150KHz- 30MHz |
B |
| LISN-32A3P |
CISPR16 |
32 |
L1,L2,L3,N |
 |
150KHz- 30MHz |
C |
| LISN-63A3P |
CISPR16 |
63 |
L1,L2,L3,N |
 |
150KHz- 30MHz |
C |
| LISN-100A3P |
CISPR16 |
100 |
L1,L2,L3,N |
 |
150KHz- 30MHz |
C |
| LISN-200A1P |
CISPR16 |
200 |
L1,N |
 |
150KHz- 30MHz |
D |
| LISN-200A3P |
CISPR16 |
200 |
L1,L2,L3,N |
 |
150KHz- 30MHz |
D |
| LISN-C25/100A |
CISPR25 |
100 |
1 |
no |
100KHz- 100MHz |
E |
| LISN-C25/500A |
CISPR25 |
500 |
1 |
no |
100KHz- 100MHz |
F |
| LISN59-41/100 |
Def Stan 59-41 |
100 |
1 |
no |
20Hz- 400MHz |
E |
| LISN461E/100A |
Mil 461E |
100A |
1 |
no |
|
E |
| Size |
| Code |
W x H x D (mm) |
Type |
| A |
180 x 80 x 300 |
Flanged box |
| B |
483 x 6u x 422 |
Instr. Case |
| C |
483 x 9u x 522 |
Instr. Case |
| D |
|
Instr. Case |
| E |
180 x 90 x 500 |
Flanged box |
| F |
180 x 120 x 500 |
Flanged box |
| Accessories |
| LISN-TS |
External transient limiter for use with LISNs
not fitted with internal transient limiter.
Insertion loss = 0dB,
Bandwidth 9KHz - 400MHz Mains supply required
|
| Voltage Probe |
| PLIP |
Power Line Interference Probe..... See separate
information sheet.
Complies with CISPR16.
Insertion loss nominally 0dB.
No restriction on EUT supply current
For use in circumstances when a LISN is not appropriate (e.g. current
>100A, permanent installation.....)
Includes 1kV isolation, transient limiter and 30dB amplifier. |
| Emission tester |
| PLIPMAN |
Complete Portable conducted emissions tester....See
separate information sheet
Includes voltage probe and emissions measuring unit giving readout
of frequency and dBuV
Enables shop-floor and on-site measurements to be made easily and
quickly.
Single phase and 3 phase operation (500V AC rms, max.)
Internal rechargeable batteries fitted and battery charger supplied. |
|